30kVA Cummins Diesel Generator

  • Home
  • 30kVA Cummins Diesel Generator

30kVA Cummins Diesel Generator

30kVA Cummins Diesel Generator
Diesel Generator

Standards: 2006/42/EC Machinery safety, 2006/95/EC Low voltage, EN 60204-1 : 2006+A1 : 2009, EN ISO 12100 : 2010, EN ISO 8528-13:2016, EN ISO 13849-1 : 2015, EN 60204-1 : 2018

PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1.

ESP: The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed.

Conditions: According to the standard, the nominal power assigned by the genset is given for 25°C air inlet temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity.

GENERATOR SPECIFICATION

ITEMSPRPEPS
Power27kVA30kVA
Power22kW24kW
Frequency / Phase / Power factor50Hz / 3P / PF0.8 
Standard voltage400/230V 
Available voltage380/220V · 415/240V 

GENERAL INSTALLATION

ITEMSOPENSILENT
Dimension (L*W*H) (mm)1800*960*14682298*954*1250
Weight (kg)8111100
Fuel tank (L)19590
Sound pressure level  
@75% load & 1m dB(A)TBATBA
@75% load & 7m dB(A)TBATBA
GENERATOR

NOTE: Weights and dimensions based on standard products. According to 2000/14/CE, sound data is provided at 7m for 75% prime power. For actual installation, please contact the manufacturer.

PERFORMANCE DATA

ItemDescription
Engine brandCUMMINS
Engine model4B3.9-G2
FuelDiesel
AspirationNaturally Aspirated
CoolingWater-cooled
GovernorElectronic
Cyl arrangement4L
ApplicationPrime & Standby
Fuel consumption
  • 100% ESP (L/H): 7.5
  • 100% PRP (L/H): 6.7
  • 75% PRP (L/H): 5.2
  • 50% PRP (L/H): 3.9

ENGINE SPECIFICATION

BASIC DATA
SpecificationDetails
Engine brandCUMMINS
Engine model4B3.9-G2
Displacement3.9L
No. of cyl / arrangement4L
Bore x stroke102×120mm
Compression ratio18.0 : 1
Engine speed1500rpm
Engine type4-stroke diesel
EXHAUST SYSTEM
SpecificationValue
Exhaust stack gas temperature (max.)410°C
Exhaust gas flow rate (max.)71 L/S
Exhaust system backpressure (maximum allowable)10 kPa
FUEL SYSTEM
SpecificationValue
Maximum restriction at lift pump13.6 kPa
Max. fuel flow30 L/H
COOLING SYSTEM
SpecificationValue
Radiator air flow60 m³/min
Total oil capacity10.9L
Total coolant capacity15.2L
ELECTRICAL SYSTEM
SpecificationValue
Starter motor rated voltageDC12V
Start battery2×60Ah (580CCA)
Battery charging alternatorDC24V / 40A
 
INLET AIR
SpecificationValue
Air filterDry type
Max. combustion air intake restriction3.2 kPa
Combustion air inlet flow rate32 L/S
Max. allowable combustion air inlet temp50°C

ALTERNATOR SPECIFICATION

BASIC DATA BASIC DATA 
Insulation & temperature riseClass H/HTypeBrushless
Excitation typeSelf-excitedNo. of bearingsSingle bearing
Winding leads12Coupling systemFlexible disc
Winding connections (standard)StarMaximum over speed2250 RPM
Winding pitchTwo thirdsCoating typeVacuum impregnation
Number of phaseThree phaseIP ratingIP23

CONTROL SYSTEM

Key features

CONTROL SYSTEM JRC
ALTERNATOR SPECIFICATION
CONTROL SYSTEM AGC -JRC

GENSET VERSION

STANDARD FEATURES

  • Diesel engine, 50 degrees radiator, brushless alternator
  • Intelligent controller
  • Output circuit breaker (up to 1250A)
  • Maintenance-free start battery, battery charge, battery switch
  • Steel industrial silencer, exhaust bellows and elbows
  • Steel chassis and anti-vibration shock absorbers
  • Lifting and moving structure, expansion of oil and coolant discharge
  • Moving parts protection, hot parts protection
  • Special toolbox, delivery attached documentation
GENSET VERSION

OPTIONAL FEATURES

ENGINE

  • Water jacket preheater
  • Oil Preheater, oil level maintainer, oil manual pump
  • Heavy air filtration
  • Residential silencer
  • Remote radiator, heat exchanger

ALTERNATOR

  • PMG/AREP excitation system
  • Anti-condensation heater
  • Winding/bearing RTD
  • Double bearing structure
  • IP44 protection class

CONTROL SYSTEM 

  • Synchronizing panel, remote control panel
  • RS232/485, 4G & GPS wireless, ethernet communication card
  • Additional digital/analog input/output
  • Monitoring software, mobile APP
  • Ni-Cad batteries

GENERATING SET 

  • External fuel tank, automatic fuel feeding
  • ATS/output /combining/distribution cabinet
  • Load test cabinet
  • Mobile trailer
  • Customized design

30kVA Cummins Powered Diesel Generator – Reliable Backup Power for Bangladesh

Looking for a 30kVA diesel generator in Bangladesh that offers reliable performance and fuel efficiency?
The CU30D5 Cummins Powered Diesel Generator, available at JRC Powertech, is your go-to solution for factories, clinics, small industries, and offices that require continuous or emergency power backup.

Built with a trusted Cummins 4B3.9-G2 engine, this generator offers long life, low maintenance, and excellent fuel economy under heavy loads.

⚡ Why Choose a 30kVA Cummins Generator?

  • Global Trust: Cummins engines are globally renowned for performance and durability.
  • Optimized for Bangladesh: Performs exceptionally in high-temperature, high-humidity, and voltage-fluctuating conditions.
  • Dual Application: Suitable for both prime power (PRP) and standby power (ESP) usage.
  • Low Fuel Consumption: Saves long-term operational costs with exceptional fuel economy.
  • Low Maintenance: Built to run reliably for years with minimal servicing.
Cummings Powered Diesel Generator

🤝 Why Buy from JRC Powertech?

JRC Powertech is a trusted diesel generator supplier in Bangladesh with over 20 years of excellence in the power sector.

  • 🔧 Local stock and fast delivery nationwide
  • 🛠️ Expert generator sizing, installation & commissioning
  • 🧰 Genuine Cummins spare parts and servicing
  • 📞 Emergency support and routine maintenance
  • 🛡️ Warranty-backed performance

💡 We don’t just sell generators. We deliver peace of mind.

Cummings Powered Diesel Generator

FAQ

What is the fuel consumption of a 30kVA Cummins generator?

At full load, it consumes approx. 6.7–7.5 liters/hour, depending on conditions.

Yes. It is designed for both prime (continuous) and standby (emergency) use.

Absolutely. A silent canopy model is available for noise-sensitive environments.

Yes. We deliver and install across all regions of Bangladesh.

Yes. It meets ISO and CE standards and is fully compatible with local requirements.

📞 Request a Free Power Consultation Today

Need help selecting the right generator for your facility?
Call our expert team at 📞 01915-491405 or Get a Free Quote now.
Let us power your business — efficiently and affordably.

At vero eos et accusamus et iusto odio digni goikussimos ducimus qui to bonfo blanditiis praese. Ntium voluum deleniti atque.

Melbourne, Australia
(Sat - Thursday)
(10am - 05 pm)